Search results for " Thrombectomy"
showing 10 items of 24 documents
Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT
2017
BACKGROUND AND PURPOSE: Large-bore catheters allow mechanical thrombectomy in ischemic stroke by engaging and retrieving clots without additional devices (direct aspiration first-pass technique [ADAPT]). The purpose of this study was to establish a model for minimal catheter diameters needed for ADAPT. MATERIALS AND METHODS: We established a theoretic model for the calculation of minimal catheter diameters needed for ADAPT. We then verified its validity in 28 ADAPT maneuvers in a porcine in vivo model. To account for different mechanical thrombectomy techniques, we factored in ADAPT with/without a hypothetic 0.021-inch microcatheter or 0.014-inch microwire inside the lumen of the aspiration…
Zakrzepica zatok żylnych — diagnostyka, leczenie farmakologiczne i alternatywne leczenie endowaskularne z zastosowaniem systemów do trombektomii
2018
Cel: Celem artykułu jest omówienie patofizjologii, obrazu klinicznego, neuroobrazowania zakrzepicy żył mózgowych oraz nowoczesnych metod leczenia, z uwzględnieniem leczenia endowaskularnego. Metody: Na podstawie dostępnego piśmiennictwa przeanalizowano wyniki leczenia farmakologicznego oraz alternatywnego postępowania endowaskularnego, obecnie wciąż zarezerwowanego dla chorych bez odpowiedzi lub z nieadekwatną odpowiedzią na leczenie farmakologiczne przeciwkrzepliwe. Wyniki: Objawy kliniczne zakrzepicy zatok żylnych są często niespecyficzne i wymagają dokładnej diagnostyki neurologicznej i obrazowej. Jest to o tyle istotne, że zakrzepica zatok żylnych występuje rzadko, dotyczy głównie młody…
Endovascular Stroke Treatment and Risk of Intracranial Hemorrhage in Anticoagulated Patients
2020
Background and Purpose— We aimed to determine the safety and mortality after mechanical thrombectomy in patients taking vitamin K antagonists (VKAs) or direct oral anticoagulants (DOACs). Methods— In a multicenter observational cohort study, we used multiple logistic regression analysis to evaluate associations of symptomatic intracranial hemorrhage (sICH) with VKA or DOAC prescription before thrombectomy as compared with no anticoagulation. The primary outcomes were the rate of sICH and all-cause mortality at 90 days, incorporating sensitivity analysis regarding confirmed therapeutic anticoagulation. Additionally, we performed a systematic review and meta-analysis of literature on this to…
Successful Management of Fulminant Pulmonary Embolism Using a Novel Portable Extracorporeal Life Support System
2010
A 46-year-old man presented to the emergency room with pain in his left leg, dyspnea, and general cyanosis. During examination he collapsed and required resuscitation. Under suspicion of pulmonary embolism, a new portable "click 'n run" extracorporeal life support system (LIFEBRIDGE-B(2)T [Medizintechnik AG, Ampfing, Germany]) was implanted by the femoral vessels under resuscitation within 15 minutes of presentation. The patient was stabilized, despite severe decompensation (pH, 6.8), and could be transferred for a computed tomographic scan, which confirmed massive pulmonary embolism. Still connected to the life support system, the patient was transferred to the operating room. After a pulm…
Mechanical rotational thrombectomy with Rotarex system augmented with drug-eluting balloon angioplasty vs. stenting for the treatment of acute thromb…
2018
Introduction Mechanical thrombectomy is an alternative to local thrombolysis for the treatment of severe ischaemia in the femoropopliteal segment, but stent implantation is usually required after this procedure. The use of drug-eluting balloons (DEBs) may overcome long-term problems associated with stents, but it remains unclear how often such a treatment is technically feasible and efficient. Aim This post hoc single-centre study was aimed at assessment of the feasibility, safety and efficacy of mechanical thrombectomy followed by application of DEBs. Material and methods Fifty-one patients, aged 69.1 ±11.6 years, were managed for acute thrombotic or chronic critical ischaemia in the femor…
Mechanical thrombectomy for rescue treatment of severe thrombosis of the superior sagittal sinus with the use of Penumbra and AngioJet catheters
2018
Open Radical Nephrectomy: 35 Years of Experience at the “Luciano Giuliani” Urological Department of the University of Genoa
2006
Objective: Radical nephrectomy remains the gold standard for surgically resectable kidney neoplasms > 4 cm and, in selected cases, also in presence of metastatic disease. We reviewed the records of the patients having surgery at the University of Genoa in the last 35 yr. Methods: We have retrospectively assessed all the radical nephrectomies performed between 1970 and 2005. Among tumours of the kidney subjected to surgical treatment during this period, we found 1105 cases of histologically proven renal cell carcinoma (RCC), 965 of which had records available for the study. The number of cases per year, symptoms at diagnosis, surgical strategy, staging of the tumour, and survival were rev…
Mechanical rotational thrombectomy in long femoropopliteal artery and stent occlusion in COVID-19 patient: Case report
2021
Abstract Introduction Coronavirus disease-19 (COVID-19) has been increasingly associated with thromboembolic complications. COVID-19 infection has a thrombogenic potential for stents. Herein, we report a case of stent thrombosis in diabetic obese patient COVID-19 positive where was previously released a Multilayer Flow Modulator stent (MFM) for large popliteal aneurysm. Case report A 78-year-old male was referred to our hospital for fever and acute pain in the left leg. At history, the same patient had endovascular procedure for a large symptomatic popliteal aneurysm, treated through release of three MFM. The pulmonary CT scan showed COVID-19 infection with confirm of rhino-laryngeal swab. …
Reduced Admissions for Cerebrovascular Events during COVID-19 Outbreak in Italy
2020
Supplemental Digital Content is available in the text.
Migration of a Fractured Acetabular Socket Wire Into the Femoral Vein: Indication for Urgent Removal by Venous Thrombectomy: A Case Report
1990
The migration of a foreign body into a great vein is a rare occurrence that requires urgent surgical intervention. In our patient one fragment of a circular acetabular socket wire marker had entered the femoral vein. Exact topographic location of the wire was achieved by computerized tomography. Urgent surgery revealed a floating wire within the venous lumen with associated thrombosis.